EZ-APAR™ AUTOMATION SOFTWARE & SERVICES
featuring
TRRP Commander INPUT™


Introducing EZ-APAR™ and EZ-APAR Plus™, our newest APAR Automation Services programs to make APAR Table Automation available to environmental consultants without the full-featured version of TRRP Commander IND™.

How does EZ-APAR™ Work?

  1. Install TRRP Commander INPUT™ software and H2A Lab Data EDD format file
    (FREE download).
  2. Enter site info (such as site name, address, land use, groundwater classification, Tier 2 input parameters, if available) into TRRP Commander INPUT™. Export Site File with the click of a single button.

  3. Use the H2A EDD format file to enter your lab data in Excel. Your lab can easily provide current data electronically in this format. Historical data can be easily copied from existing Excel worksheets.

  4. E-mail Site File, Lab Data EDD, and Site Map to H2A.

  5. Receive Completed TRRP Screening, Calculations & APAR Worksheets optimized by H2A‘s TRRP expert in an electronic format ready to Insert in YOUR APAR.
What is EZ-APAR Plus™?

After using the EZ-APAR tables to create your APAR, have H2A’s TRRP expert review your draft APAR and suggest changes to text, maps, and tables to make sure that the TCEQ, and your client, is happy with your submittal.

Email Our Sales Dept.
EZ APAR™ Pricing for LPST and Dry Cleaner Sites
TRRP Commander INPUT™ and Lab Data EDD Software One (1) Single User License FREE  
Time Client Setup Fee One-time fee per company
(at time of 1st APAR)
$ 195.00
EZ-APAR Tables
per site $ 595.00
EZ-APAR Plus H2A TRRP -- Expert review of draft APAR    
  Review - no major changes necessary
(typos, etc.)
$ 795.00
  Review - major changes suggested
(text revisions, etc.)
$ 1995.00
Additional Fees – Importing Lab Data from EDD
(first file)
$195
  – Importing each additional EDD file $95
  – Reprint APAR Tables
(if reprocessed with new data)
$295
  – Surface Water related APAR Tables $595
  – Database File Export for TCEQ Submittal $95


Download EZ APAR™ Software

EZ
APAR™ Comprehensive System Features:
Email Our Sales Dept.

The following "spec" sheet for EZ APAR™ will show you the extensive capabilities and deliverables for this program. Plus you are assured of the high standard of technical quality and accuracy that H2A and TRRP Commander IND™ provide. After all, the Texas Commission on Environmental Quality (TCEQ) purchased 100 licenses for TRRP Commander IND™ to facilitate their APAR reviews. EZ APAR™ uses the same software to automate your APAR worksheets that TCEQ purchased to review them.
1. Database Format
Allows the inputs and calculated results for hundreds (or thousands) of sites to be stored in one software application file with a sortable site list for easy retrieval. Data tables reside in separate file from user interface application file to allow data tables to be placed on a server while the application runs on each licensed workstation.
2. Site List Management
The Site List can be filtered by any user by entering information in the input boxes provided on the Site List form. Input boxes are provided for Site Number, Site Coordinator, Responsible Person, County, and TCEQ Region. Partial entries are accepted (for example, entering “Exx” in the Responsible Person’s input box would restrict the Site List to Exxon or ExxonMobil sites).

3. Separate Scenarios for On-Site and Off-Site
For each site, a separate scenario can be created for both on-site and off-site conditions. In each scenario the user is given the choice of:
--Residential or Commercial/Industrial Receptors
--Complete Exposure Pathways
-- Groundwater Classification
-- Site-Specific Input Parameters
4. Updated Tier 1 Tables
Each TCEQ update of chemical toxicity and physical property tables is available for use as the basis of PCL calculations. The date of the update selected is stored for display on reports as required in APAR formats.
5. Lab Data Statistics
Chemicals can be added to the list of COCs manually from a drop-down list of chemical names or CAS numbers or electronically from data links with DATA CommanderTM. Input screens are available for the manual entry of
-- a. maximum concentration,
--b. representative concentration,
--c. maximum SQL of non-detect samples,
--d. MQL
--e. number of samples, and
--f. number of detections
6. Automated Site Export
To send the information for a site to H2A for APAR automation services, simply click the Export Site button, save the file when prompted, and e-mail to support@h2altd.com.

 

APAR Automation Services
Upon receipt of the exported site information, H2A will conduct risk assessment calculations and APAR table generation, including the following scope of work.
--• Exposure pathway analysis
----o Considering site conditions
----o Considering existing or proposed physical controls
--• Tier 2 modeling and PCL calculations for the following pathways:
----o Total Soil Combined pathways
----o Inhalation of Vapors from Subsurface Soil
----o Leaching from Soil to Groundwater
----o Ingestion of Groundwater (or Class 3 Groundwater)
----o Inhalation of Vapors from Groundwater
--• PCL calculations for TPH using the results of TX1006 analysis
--• Calculate Residential Assessment Levels
----o including Tier 2 Soil-to-Groundwater PCLs or, if Source Area is greater than 30 acres, including Tier 2 PCLs for all pathways
----o including the substitution of the MQL, Texas background concentration, or site-specific background concentration if greater than calculated assessment level
--• COC-Screening - identify chemicals that do not require PCL calculations
----o Chemicals with all detected values and SQLs below the assessment levels
----o Chemicals with no detections and SQLs below the assessment levels
----o Chemicals which qualify for other screening criteria
--• Optimize critical PCLs for each COC
----o Select Tier with most favorable result (this can be done independently for each exposure pathway and each COC)
----o Calculate critical PCLs including the substitution of the MQL, Texas background concentration, or site-specific background concentration if greater than calculated PCL
--• Generate and deliver APAR tables in PDF format
---- APAR Worksheet 4.0 – Exposure Pathways
---- APAR Worksheet 4.2 – Screening COCs from PCL Development (multiple tables)
---- APAR Worksheet 5.0 – Soil Assessment Levels
---- APAR Worksheet 5.1 – Surface Soil COC Summary
---- APAR Worksheet 5.2 – Surface Soil PCL Evaluation (multiple tables)
---- APAR Worksheet 5.3 – Surface Soil Risk Level and Hazard Check
---- APAR Worksheet 5.4 – Surface Soil and Subsurface Soil PCL Evaluation
---- APAR Worksheet 5.5 – Critical Surface Soil PCLs
---- APAR Worksheet 5.6 – Subsurface Soil COC Summary
---- APAR Worksheet 5.7 – Subsurface Soil PCL Evaluation (multiple tables)
---- APAR Worksheet 5.8 – Subsurface Soil Risk Level and Hazard Check
---- APAR Worksheet 5.9 – Critical Subsurface Soil PCLs
---- APAR Worksheet 6.0 – Groundwater Assessment Levels
---- APAR Worksheet 6.1 – Groundwater COC Summary
---- APAR Worksheet 6.2 – Groundwater PCL Evaluation (multiple tables)
---- APAR Worksheet 6.3 – Groundwater Risk Level and Hazard Check
---- APAR Worksheet 6.4 – Critical Groundwater PCLs
---- APAR Worksheet 7.1 – Surface Water and Sediment COC Summary
---- APAR Worksheet 7.2 – Surface Water and Sediment PCL Evaluation
---- Appendix 4 – Assessment Levels for Screened COCs
---- Appendix 4 – Total Soil Combined pathways support calculations
---- Appendix 4 – Surface Soil Volatilization Factor and Csat support calculations
---- Appendix 4 – Subsurface Soil Volatilization Factor support calculations
---- Appendix 4 – Groundwater Volatilization Factor support calculations
---- Appendix 4 – Critical PCL support calculations for Surface Soil, Subsurface Soil, and Groundwater
---- Appendix 4 – PCL calculations for TPH using the results of TX1006 analysis

Download EZ APARTM Software
Email Our Sales Dept.

Home - Company - History & Qualifications - Projects - Bios & Media Page - Products & Services
High Vacuum Remediation - Risk Assessment - Software - Other Services - Contact

©H2A Environmental, Ltd., 2001-2002
1862 Keller Parkway, Keller, Texas 76248
Phone : 682-593-0220
Fax: 682-593-0660
info@h2altd.com